Arm-electronics SDKBD1 Instrukcja Użytkownika Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 11
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
- 4 -
1. Select Address of Speed Dome Camera /Decoder[N]+[ CAM]
DescriptionN –– No. of camera from 0 to 64
FunctionSelect the address of the camera to be controlled. When the value N is in conformity with the
address of the speed dome, it will be under control.
2. To set preset position[N]+[ PRESET]
DescriptionN –– No. of preset position from 1 to 64.
FunctionStore current position and refer it as No. N position.
3. Call the Preset position[N]+[ CALL]
Description:N –– No. of preset position from 1 to 64.
Function Transfer the camera to the position of No. N preset position.
4. Cancel the Preset position: [N]+[CLEAR]
DescriptionN –– No. of preset position from 1 to 64.
FunctionDelete the No. N Preset position stored.
5. Run patrol[N]+ [SHOT]
DescriptionN –– No. of the track from 1 to 3.
FunctionTour the No. N track and stop tour by pushing the joystick.
6. To turn on Auto Pan (Operation of COP-2 SAMSUNG Protocol)[AUTO]+[P1]+[ON]+[P2]+[OFF]
DescriptionP1 –– the starting scan No. of preset point from 1 to 64, which should be set already.
DescriptionP2 – the ending scan No. of preset point from 1 to 64, which should be set already. If P1 =
P2 or P1 and P2 are coincided, the speed dome will make scan in range of 360°.
Note:
For PELCO-DPELCO-PCOP-1 Protocol the way of operation is as follows:
Set the starting scan position: Transfer the Speed Dome to the starting scan position, operation
[AUTO]+[ON]
Set the ending scan position: Transfer the Speed Dome to the ending scan position, operation
[AUTO]+[OFF]
Run Auto Pan[AUTO]+[SHOT]
Auto Pan operation takes the following parameters. You must set these parameters before using a
Auto Pan command to begin the scan operation. You can use the scan stop command or PT swing
stop command to stop the scan. Setting scan condition.
z Auto Pan Position (First specify position, second specify position)
z Auto Pan Speed and Direction
7. Stop Auto Pan[AUTO]+[OFF] ( Only C0P-2 Available) or push the joystick to stop scan
8. Patrol setup (COP-1, COP-2, PELCO-D, PELCO-P Available)
a) Set Patrol Start[96] + [CALL] Begin to set the No.1 patrolLED Display L1
[97] + [CALL] Begin to set the No.2 patrolLED Display L2
[98] + [CALL] Begin to set the No.3 patrolLED Display L3
b) Insert preset point in patrolif LED display LNN: No. of the patrol from 1 to 3.you can insert
preset point in current patrol. Now you can operate as follow:
[N] + [CALL] (N: No. of preset position from 1 to 64). And you can insert 16 preset point in
maximum
c) Set Patrol Stop: [99] + [CALL]
9. Control the zoom of the Camera[WIDE]/[TELE]
10. Control the Focus of the Camera[FAR]/[NEAR]
11. Control the Iris of the Camera[OPEN]/[CLOSE]
Przeglądanie stron 6
1 2 3 4 5 6 7 8 9 10 11

Komentarze do niniejszej Instrukcji

Brak uwag